Inside the back cover of the BRC4C160, there is a small bank of DIP switches. The installation manual explains each one:
| Switch | Setting | Function | |--------|---------|----------| | DS1-1 | OFF (default) | Temperature sensor: Uses indoor unit sensor | | DS1-1 | ON | Temperature sensor: Uses remote controller’s built-in sensor | | DS1-2 | OFF | Standard operation | | DS1-2 | ON | Celsius / Fahrenheit selection (ON = Fahrenheit) | | DS1-3 | OFF | No function (reserved) | | DS1-4 | OFF | Normal mode |
Critical: If the system reads room temperature incorrectly (e.g., cold location near a door), set DS1-1 to ON to use the remote’s local sensor.
Q: Does the BRC4C160 work with a Daikin heat pump? A: Yes. In Heat mode, the remote shows “☀” and controls the reversing valve. Daikin Brc4c160 Manual
Q: Can I use my smartphone as a remote instead? A: Only if you have a Daikin Wi-Fi adapter (BRP069A41/42) installed. The BRC4C160 itself does not have wireless capability.
Q: What should I do if the room temperature differs from the remote reading? A: Check DIP switch DS1-1. If set to OFF, the remote uses the indoor unit’s return air sensor. If that sensor is dirty or poorly located, switch to ON to use the remote sensor.
Q: Where is the serial number on the BRC4C160? A: On a sticker located on the backplate, behind the remote body. You must gently pull the remote off the wall plate. Inside the back cover of the BRC4C160, there
Q: My manual is in Japanese – where is English? A: Daikin Japan often includes multi-language. Download the specific regional version from Daikin Europe or Daikin US.
| Error Code | Meaning | Possible Fix | |------------|---------|---------------| | U0 | Refrigerant shortage (low pressure) | Check for leaks; call technician | | U2 | Power supply voltage drop | Inspect indoor unit power supply | | U4 | Communication error between indoor and outdoor units | Check wiring; cycle power | | A1 | Indoor unit PCB malfunction | Replace indoor board | | A5 | High-pressure protection or frozen coil | Clean filters; check airflow | | C4 | Thermistor (temperature sensor) error | Replace thermistor in indoor unit | | E5 | Locked fan motor | Turn off power and free the fan | | F3 | Drain pan overflow | Clear drain line; check float switch |
If you see a code not listed here, the manual has a complete table. Alternatively, hold the "Cancel" button for 5 seconds to reset the error after the issue is resolved. Critical: If the system reads room temperature incorrectly
If you prefer offline access or a printed copy:
Before diving into settings, let’s decode the dashboard. Here are the most common buttons you will use: